Generator Size Calculator: What Size Generator Do I Need?

Most homes that only back up essentials (fridge, sump pump, furnace blower, lights, internet) need about 3,500 running watts and 4,500 surge watts. Adding central air or a well pump usually pushes you to 7,500–12,000 W or a home standby unit. Check your own mix below.

What do you need to power during an outage?

Wattages shown are typical values. For your exact appliance, use the nameplate figures in "Custom load". How we calculate

Essentials
Kitchen
Heating & cooling
Water & pumps
Laundry
Comfort
Electronics
Garage & workshop
Custom load (from the nameplate)

Only have amps? Enter RLA and LRA from the compressor label instead:

Assumptions
Generator running watts–
Surge (starting) watts–
Suggested type–

See the load breakdown
LoadRunning WStart-up surge W% of load

How this calculator sizes a generator

Every generator has two numbers on its spec sheet: running (rated) watts, the power it can deliver continuously, and starting (surge) watts, the extra it can deliver for a few seconds. Your house has the same two numbers. The calculator adds them up the way manufacturer sizing guides do:

  1. Add the running watts of everything that may be on at the same time.
  2. Add the start-up surge of the largest motor. Refrigerators, freezers, sump and well pumps, furnace blowers and air conditioners all draw a spike when their motor starts. Because motors rarely start in the same second, only the biggest spike is added. If you choose “at the same time”, every spike is added instead — the worst case.
  3. Leave headroom. Running a generator at 100% of its rating for hours shortens its life and leaves no margin for a motor kicking on. By default the result keeps your continuous load at 80% of the generator’s rating.

The two numbers in the result are what you compare against a spec sheet: the generator’s running watts must be at least the first figure, and its surge watts at least the second.

Why the biggest motor decides the size

Look at the breakdown table in a typical essentials setup — refrigerator, 1/2 HP sump pump, furnace blower, LED lights, router and phone chargers. The running load is only about 2,800 W, but the refrigerator’s compressor adds roughly 1,500 W for a moment when it starts. That spike, not the steady load, is what trips an undersized generator. With 80% headroom, the recommendation lands near 3,500 running watts and 4,500 surge watts — the territory of a mid-size inverter generator.

Swap in a 3-ton central air conditioner and the picture changes completely. An older 3-ton compressor can draw more than 10,000 W for a fraction of a second at start-up. That single load can double the size of generator you need — which is why the next section matters.

Central AC and heat pumps: use the nameplate

Generic wattage charts are a starting point, but air conditioners vary too much for a chart to be reliable. The outdoor unit has a nameplate with two figures you can use in the custom load box:

  • RLA (rated load amps): current while running. Running watts ≈ RLA × volts.
  • LRA (locked rotor amps): current at the instant of start-up. LRA × volts is a conservative upper bound for starting watts.

For example, a compressor labelled RLA 14.1 A and LRA 76 A at 240 V runs at about 3,400 W and may demand up to 18,200 W at start-up. A soft starter — a small device an HVAC technician wires into the compressor circuit — ramps that start-up current instead of letting it spike. Manufacturers typically claim reductions of 60–75%; the calculator assumes 60% to stay conservative. On a large compressor this is often the difference between needing a home standby unit and getting by with a large portable.

120 V vs 240 V loads

Most household items run on 120 V. Well pumps, central AC, electric dryers, ranges and water heaters usually run on 240 V. If you select any 240 V load, the calculator flags it and only lists generators that provide 240 V.

Powering 240 V loads — or any circuit in your panel — means connecting the generator to your home’s wiring. That requires a transfer switch or an interlock kit installed by a licensed electrician. Plugging a generator into a dryer outlet (“back-feeding”) can energize the utility lines and seriously injure line workers, and can start a fire in your home.

Fuel and elevation change the real output

The same generator does not produce the same power on every fuel. Dual-fuel portables are rated lower on propane than on gasoline, and home standby units are rated lower on natural gas than on propane. Choose the fuel you will actually use and the model list uses that rating.

Altitude matters too. Engines breathe less oxygen in thin air; a common rule of thumb is a loss of roughly 3–4% of output per 1,000 ft above sea level (the calculator uses 3.5%). At 5,000 ft that is about 17% less power — enough to turn a comfortable match into an overloaded one. Your owner’s manual gives the exact derating for your engine.

Common sizing mistakes

  • Adding up every appliance in the house. You do not run the dryer, oven, water heater and AC at the same time during an outage. Size for what will realistically be on together, and use load management (or a smart transfer switch) to stagger big loads.
  • Ignoring start-up surge. A generator that covers the running total can still stall when a pump starts. Always check the surge figure.
  • Using the “maximum” watts as the running rating. Marketing headlines often show the peak figure. The running (rated) figure is the one that matters for hours of use.
  • Forgetting medical and well-water needs. If someone in the home relies on a CPAP or other device, or your water comes from a well, put those loads first and size around them.
  • Running the generator in a garage or near a window. Generator exhaust contains carbon monoxide. Keep it outdoors, far from doors, windows and vents, and install battery-backed CO alarms.

What to do with your result

Use the running and surge figures to shortlist models, then compare them on fuel, noise, runtime and transfer options. If your result lands above about 12,000 running watts or includes central air, get a quote for a home standby generator and ask the installer to confirm the unit’s motor-starting (LRA) capability against your AC’s nameplate. If it lands below 3,500 W with no 240 V loads, a portable inverter generator or a large portable power station may be enough — and both are quieter and easier to live with.

Frequently asked questions

What size generator do I need to run a refrigerator?

A typical refrigerator runs on about 700 W but needs roughly 2,200 W for a few seconds when the compressor starts. On its own, a 2,200-surge-watt inverter generator can handle it; once you add other loads, size for the total running watts plus the largest single start-up surge.

Will a 7,500-watt generator run my whole house?

It can run the essentials of most homes and sometimes a small central AC, but not everything at once. Electric water heaters, ranges and dryers each draw 2,500–5,400 W. Use the calculator with everything you expect to run at the same time to see the real number.

What is the difference between running watts and starting watts?

Running watts are what an appliance draws continuously. Starting (surge) watts are the brief spike an electric motor needs to get moving — often two to three times the running figure for compressors and pumps. A generator must cover both.

Do I need a 240-volt generator?

Only if you want to power 240 V loads such as a well pump, central AC, electric dryer or electric water heater. Many portable units above about 5,000 W have a 240 V outlet; every home standby generator supplies 240 V. Either way, connecting to your panel requires a transfer switch or interlock installed by a licensed electrician.

Does a generator produce less power on natural gas?

Yes. Natural gas carries less energy per cubic foot than propane, so the same generator is rated lower on natural gas. Compare ratings on the fuel you will actually use — the calculator does this when it lists matching models.

Sources

  1. U.S. Energy Information Administration — Open Data (fuel prices, utility reliability)
  2. TODO verify: manufacturer wattage reference chart (link the exact PDF/page you used)
  3. TODO verify: portable generator safety guidance from a federal agency (CPSC/OSHA page URL)

TODO Real Name — TODO e.g. Founder & data editor

TODO Two or three honest sentences: who you are, why you built this site, how you work with public data and manufacturer specs. No fake credentials.